22 Years' Battery Customization

What should I pay attention to in battery aging test?

Dec 18, 2023   Pageview:16

Several factors require attention when conducting battery aging tests;

Temperature Control- maintaining consistent and controlled temperatures is important to simulate real-world conditions.  the battery's lifespan is affected by extreme temperatures. Higher temperatures can accelerate battery aging while low temperatures slow down the electrochemical processes causing stress on the batteries.

Cycling Parameters- the charging and discharging cycles and rates are defined to mimic realistic usage patterns. It should be noted that each complete cycle contributes to battery aging as charge-discharge cycles affect battery health.

Monitoring and Data Collection- regular monitoring and Data Collection should be done on capacity, voltage, internal resistance, and current to keep track of degradation.

Safety measures- the risks associated with battery testing should be mitigated by ensuring proper safety protocols are in place.

State of charge- the state of charge should be assessed on battery aging. Both high and low states of charge might influence battery aging differently.

Environmental factors- environmental conditions such as humidity and vibration that can impact battery life should be considered. Some environmental conditions lead to corrosion which can accelerate battery aging.

Test Duration- the tests should be conducted for an appropriate period to simulate long-term usage and aging effects.

Analysis and Interpretation- Analyzing the collected data will help understand the degradation patterns and predict the battery's life expectancy.

3.2V 20Ah Low Temperature Square LiFePO4 Battery Cell
3.2V 20A Low Temp LiFePO4 Battery Cell -40℃ 3C discharge capacity≥70% Charging temperature:-20~45℃ Discharging temperature: -40~+55℃ pass acupuncture test -40℃ maximum discharge rate:3C

Documentation- the records of the testing process should be kept and the results for future reference and comparison.

These factors should be given enough attention to ensure that the results from the battery aging test are comprehensive and accurate.  Temperature control, environmental factors, cycling parameters, and test duration have an impact on battery aging and should be checked effectively.

Proper monitoring and analyzing these factors help provide a comprehensive understanding concerning battery aging which is important for developing more durable and robust battery technologies.

Determine Test Criteria

Various parameters are included in the test criteria for battery aging experiments to assess the battery degradation and performance.

Capacity Retention- this involves measuring how much of the original battery capacity is maintained over a given duration.  

Cycling Efficiency- the efficiency in energy retention of charge and discharge cycles should be analyzed.

Internal resistance- the battery's ability and capacity to deliver power should be affected by an increase in internal resistance that should be analyzed.  

Voltage and Current Behavior- monitor current handling capabilities, self-discharge rates, and voltage sag. The impact of high currents should be monitored for situations that might require robust energy.

Temperature Sensitivity- observe and evaluate how temperature changes affect the performance of the battery and degradation rate.

Low Temperature High Energy Density Rugged Laptop Polymer Battery 11.1V 7800mAh
Low Temperature High Energy Density Rugged Laptop Polymer Battery Battery specification: 11.1V 7800mAh -40℃ 0.2C discharge capacity ≥80% Dustproof, resistance to dropping, anti - corrosion, anti - electromagnetic interference

Cycle Life- determine the number of charge-discharge cycles endured by the battery before significant degradation occurs.

Safety performance- the battery stability and safety should be assessed under different conditions.

It is important to set specific pass or fail thresholds and acceptable ranges for every criterion to understand whether a battery needs improvement or further evaluation or has reached the end of its useful lifespan.

Select the Appropriate Test Equipment

The following factors should be considered when selecting test equipment for battery aging testing.

Battery tester/cycler- a tester that suits the test requirements and battery chemistry should be selected for capacity measurement and charge-discharge cycling.

Data Acquisition System- A system to collect real-time data is chosen to get data on current, temperature, voltage, and capacity during the tests.

Environmental chambers- chambers are used to control humidity and temperature for simulating different conditions of operations.

Impedance Spectroscopy Analyzer- this is used to measure internal resistance and impedance changes within the battery.

Safety Monitoring Equipment- ensure that safety devices are available for overvoltage, overcurrent, and temperature monitoring.

Electrochemical analysis tools- for in-depth electrochemical analysis, equipment such as impedance analyzers and potentiostats are used.  These tools are applicable where there is a need for further electrochemical analysis.

Monitoring and Measurement Tools- these are for providing a comprehensive view of the battery's performance. The measurement tools include logging devices, thermal cameras, and multimeters.

The kind of batteries under evaluation and the specific goals for the battery aging tests determine the choice of test equipment as they should align.  The chosen equipment should offer reliability, accuracy, and compatibility with the testing conditions and battery chemistry.

Standardize the Test Operation Process

The following steps should be followed to standardize the test operation process for experiments on battery aging.

Protocol Development- a comprehensive testing protocol should be defined providing details on equipment, data collection methods, procedures, and safety measures.

Equipment Calibration- to guarantee accurate measurements and results, it's crucial to ensure that all testing equipment is calibrated and validated before the experiments.

Operational Parameters- for maintaining uniformity throughout the tests, consistent parameters should be set for cycling rates, temperature, and environmental conditions.

Sample Preparation- battery preparation should be standardized to ensure identical initial conditions for each unit tested.

Data Collection- a schedule for data collection is established at regular intervals while specifying the metrics to be recorded.  

Safety Protocols- standardized safety protocols should be implemented for handling batteries during charging and discharging cycles.

Documentation- a system should be created for recording and organizing data, observations, and any deviations noticed from the standard process.  

Quality Control Checks- to verify the reliability and accuracy of the testing process, periodic control checks should be incorporated.  

Following a standardized operation process for battery aging experiments will ensure accuracy, consistency, and results comparability across various experiments and tests. The results comparability is crucial for advancements and improvements in battery technology.

Conclusion 

Several factors require attention when conducting a battery aging test.  These include the temperature, cycling Parameters, safety measures, environmental factors, test duration, and documentation of the results for future reference. Monitoring and analyzing these factors provide enough information related to battery aging which is crucial for the development of durable technologies.

The test criteria involve various parameters such as cycling efficiency, capacity retention, voltage and current behavior, temperature sensitivity, and cycle life among others. The test equipment used are also several and it depends on the expected results. The chosen equipment should offer reliability, accuracy, and compatibility with the testing conditions and battery chemistry.

*
*
*
*
*

Leave a message

Contact Us

* Please enter your name

Email is required. This email is not valid

* Please enter your company

Massage is required.
Contact Us

We’ll get back to you soon

Done