Fara capacitor discharge simple calculation method super capacitor characteristics
The volume is small, the capacity is large, and the energy density is much larger than the electrolytic capacitor.
Can be used as a backup power source, the ESR is small, the power characteristics are good, and the power density is much larger than the battery. It can be used as the power compensation of the main power supply to ensure the short-time and high-current needs. The number of charge and discharge times is more than 100,000 times.
Overcharge and overdischarge will not affect its electrical performance. Simple to use, no special charge and discharge control circuit is required green, non-polluting maintenance-free.
The operating temperature range is large, and the minimum operating temperature is minus 40 degrees Celsius.
Simple calculation method of farad capacitor discharge
T=(C&TImes;ΔU)/IT: discharge time, unit sC: capacitance capacity, unit F
ΔU: Voltage drop, the difference between the highest working voltage and the lowest working voltage, unit VI: discharge current, unit A