What does 100AH/12V battery mean?

Feb 14, 2019   Pageview:1432

The storage battery100 ah / 12V: it means that the battery capacity is 100 ah, the discharge voltage of the battery is 12V.

Battery parameters: the definition of A small electric storage battery in mAh nominal capacity (mA h.), large storage battery of nominal capacity to Ann (a. h), when kiloampere (kA h.), telecom industry often take C10, C8 and nominal capacity value. For example, a common Deka 12 avr100sh for 12 v battery monomer, 100 a. h capacity, 10 h, can continue to discharge current of 10 a, released an hours for 10 * 10 = 100 a. h (actual tests, to make current value to keep steady, when voltage change, should be adjusted external load, so that measurement).

Battery: chemical energy into electrical energy device is called chemical battery, commonly referred to as "for the battery. After discharge, can make the internal active substances in charging way - to store the electric energy to chemical energy regeneration; When need to discharge to convert chemical energy to electrical energy again. Call this type of battery storage battery (storage battery), also known as the secondary battery.

OGB submitting the 12 v - 100 ah battery is a battery, the use of special plate grid alloy, make it has good corrosion resistance. Have longer service life. Can be used arms power supply, medical equipment, monitoring systems, communications equipment and so on.

OGB submitting - UPS battery FM valve-control sealed lead-acid battery in accordance with the following criteria:

Low absorption type seal fixed lead battery cathode JISC8707-1992 standard

Low JB/T8451-96 standard of the People's Republic of China machinery industry

Low YD/T799-2002 communication industry standards of the People's Republic of China

Low DL/T637-1997 communication industry standards of the People's Republic of China

UPS uninterruptible power supply battery arms power supply

Medical equipment monitoring and control system

Communications equipmentspecial/navigation system

The petrochemical industry plant/plant, etc

Low OGB submitting - UPS battery maintenance free life need not add acid water).

Use strict production process, monomer voltage balance.

The use of special plate grid alloy, good corrosion resistance and deep circulation performance, with low self-discharge.

Low adsorption type glass fiber technology makes the gas recombination efficiency is as high as 99% and low internal resistance, excellent large current discharge performance.

Low OGBUPS battery before use check appearance crack, breakage, leakage phenomenon, should be timely find the reasons or be replaced when found.

Low OGBUPS battery should be installed far away from fire, heat source (greater than 2 m), must have good exhaust ventilation conditions, temperature should ensure that the battery operation environment in 15 to 25 degrees. Make a longer battery life.

Low voltage, charging current time according to the factory regulations, discharge the battery to avoid overcharge.

Handling, installation, should avoid the battery is in use process, negative electrode short circuit.

Low OGB submitting disassembling battery should be done by professionals, if the battery electric hydraulic mechanical damage on the skin or the clothes. Rinse immediately with water. If the eyes, flush with plenty of water and immediately to hospital as soon as possible treatment.

Low different capacity, different manufacturers or different batteries do not mix old and new.

Don't take low fiber cloth or sponge to wipe the battery shell.

Low battery park put aside more than six months, before use must be added.

The charging characteristics

6 FM series sealed battery has good discharge characteristic, especially the characteristics of large current discharge is superior. The battery discharge capacity depends on the discharge current, termination voltage and discharge time.

The discharge performance of different discharge rate and termination voltage option below:

Self-discharge features

6 FM series sealed battery has good discharge characteristic, especially the characteristics of large current discharge is superior. The battery discharge capacity depends on the discharge current, termination voltage and discharge time.

The charging characteristics

6 sealed batteries require the use of FM current-limiting constant-voltage charging methods for charging. In the environment under the condition of 25 ℃, the best float charging voltage of 13.6 + / - 0.1 V X sets, at the beginning of the charging current should be limited in the range of 0.25 C10A.